-
SKU: BUNDLE-CONDENSATE-001
Condensate System Service Kit — Pump + Float Switch + Drain Pan Tablets — HVAC Bundle
$71.97$64.77 -
DiversiTech
SKU: CCT-34
Diversitech Condensate Drain Line Clean-Out Tee with Cap 3/4 Inch – HVAC Drain – Fast Ship
$8.99 -
DiversiTech
SKU: CT-34-T
Diversitech 3/4 Inch PVC Condensate Drain Tee – HVAC Drain Fitting – Fast Ship
$8.99 -
DiversiTech
SKU: CE-34-90
Diversitech 3/4 Inch PVC Condensate Drain Elbow 90-Degree – HVAC Drain Fitting – Fast Ship
$2.99 -
DiversiTech
SKU: CT-34-50
Diversitech 3/4 Inch ID Clear Vinyl Condensate Drain Tubing 50 Ft – HVAC Drain Line – Fast Ship
$30.99 -
DiversiTech
SKU: CT-34-25
Diversitech 3/4 Inch ID Clear Vinyl Condensate Drain Tubing 25 Ft – HVAC Drain Line – Fast Ship
$16.99 -
DiversiTech
SKU: SL-2
Diversitech SL-2 Condensate Overflow Safety Switch – HVAC Float Switch – Fast Ship
$16.99 -
DiversiTech
SKU: SL-1
Diversitech SL-1 Condensate Overflow Safety Switch – HVAC Float Switch – Fast Ship
$14.99 -
DiversiTech
SKU: CP-22
Diversitech CP-22 Mini Condensate Pump 115V – Compact HVAC Drain Pump – Fast Ship
$69.99 -
Little Giant
SKU: VCMX-20ULS
Little Giant VCMX-20ULS Condensate Removal Pump 115V – HVAC Drain Pump – Fast Ship
$99.99 -
Little Giant
SKU: VCMA-20ULS
Little Giant VCMA-20ULS Condensate Removal Pump 115V 1/30 HP – HVAC Drain Pump – Fast Ship
$89.99 -
DiversiTech
SKU: CP-22LC
Diversitech CP-22LC Condensate Pump – 22 GPH 115V HVAC Pump with Safety Switch and Alarm
$125.59 -
Value Collection
SKU: 554631
Condensate Systems; Type: Condensate Pump; Voltage: 230 VAC; Tank Capacity: 1.5 Qts.; GPM: 1.33; Outlet Size: 3/8 Barbed; Gpm: 1.33; Cord Length: 6; GPH @ 1 Foot of Head: 78.000; GPM @ 10 Feet of Head: 51; GPM @ 5 Feet of Head: 67; Gph At 1 Foot Of H
$142.72 -
Value Collection
SKU: 554650
Condensate Systems; Type: Condensate Pump; Voltage: 115 VAC; Tank Capacity: 1.5 Qts.; GPM: 1.40; Outlet Size: 3/8 Barbed; Gpm: 1.40; Cord Length: 6; GPH @ 1 Foot of Head: 84.000; GPM @ 10 Feet of Head: 60; GPM @ 5 Feet of Head: 75; Gph At 1 Foot Of H
$147.69 -
Value Collection
SKU: 554630
Condensate Systems; Type: Condensate Pump; Voltage: 115 VAC; Tank Capacity: 1.5 Qts.; GPM: 1.40; Outlet Size: 3/8 Barbed; Gpm: 1.40; Cord Length: 6; GPH @ 1 Foot of Head: 84.000; GPM @ 10 Feet of Head: 60; GPM @ 5 Feet of Head: 75; Gph At 1 Foot Of H
$142.72 -
Value Collection
SKU: 554461
Condensate Systems; Type: Condensate Pump; Voltage: 230 VAC; Tank Capacity: 1/2 Gal.; GPM: 1.33; Outlet Size: 3/8 Barbed; Gpm: 1.33; Cord Length: 6; GPH @ 1 Foot of Head: 80.000; GPM @ 10 Feet of Head: 48; GPM @ 5 Feet of Head: 70; Gph At 1 Foot Of H
$153.89 -
Value Collection
SKU: 554415
Condensate Systems; Type: Condensate Pump; Voltage: 115 VAC; Tank Capacity: 1/2 Gal.; GPM: 1.08; Outlet Size: 3/8 Barbed; Gpm: 1.08; Cord Length: 6; GPH @ 1 Foot of Head: 65.000; GPM @ 10 Feet of Head: 25; GPM @ 5 Feet of Head: 50; Gph At 1 Foot Of H
$131.56 -
Value Collection
SKU: 554401
1/2 Gallon without Safety Switch Tank Capacity, 115 Volt, 15 Shutoff Pump, Condensate System
$91.72 -
$266.78
-
Value Collection
SKU: 554435
Condensate Systems; Type: Condensate Pump; Voltage: 115 VAC; Tank Capacity: 1/2 Gal.; GPM: 1.08; Outlet Size: 3/8 Barbed; Gpm: 1.08; Cord Length: 6; GPH @ 1 Foot of Head: 80.000; GPM @ 10 Feet of Head: 48; GPM @ 5 Feet of Head: 70; Gph At 1 Foot Of H
$150.17 -
$94.46
-
$285.39
-
$623.41
-
$152.74
Condensate Management
(Showing 24 of 26)Professional HVAC Condensate Management
Source high-performance condensate pumps, drain pan tablets, PVC gravity drain fittings, and flexible condensate tubing designed for reliable system moisture removal.
Procurement & Sourcing Notice
We help source commercial-grade condensate pumps and management supplies from leading drainage manufacturers. Flow rates, lift capacity, and voltage must be verified prior to installation. Always ensure condensate drainage complies with local plumbing and environmental codes.
Explore Sourcing Categories
Drain Pan Tablets
Source slow-dissolving drain pan tablets engineered to prevent slime, algae, and biological blockages in condensate pans and lines.
Humidifiers & Dehumidifiers
Commercial-grade moisture control systems that require robust condensate drainage and pumping solutions for continuous operation.
Refrigerant Fittings & Valves
Source high-integrity fittings and valves required for refrigerant control and system integration across all cooling systems.
Professional Sourcing Overview
Condensate management is a critical but frequently overlooked aspect of HVAC system design, installation, and preventative maintenance. Air conditioning and refrigeration systems extract massive volumes of moisture from the air during the cooling cycle. If this condensate is not routed away from the building quickly and reliably, it can lead to overflow, resulting in catastrophic drywall damage, structural wood rot, and hazardous mold growth. Sourcing commercial-grade condensate pumps and drainage accessories is essential to protecting property assets and ensuring continuous system operation.
Our condensate management catalog includes automatic condensate pumps with high-lift capabilities, designed to pump water vertically when gravity drainage is not feasible. We also source slow-dissolving drain pan tablets that actively treat standing water, preventing the biological slime and algae buildup that causes line blockages. From heavy-duty PVC fittings and flexible vinyl tubing to electronic overflow safety switches that shut down the HVAC system in the event of a backup, our supplies provide complete water damage protection.
Who We Serve
Residential Installers
Install reliable condensate pumps and secondary drain pan overflow switches to protect attics and ceilings from water damage.
Commercial Service Techs
Perform routine maintenance by clearing clogged lines, replacing worn-out pumps, and applying commercial drain pan treatments.
Property Managers
Prevent costly tenant water damage claims by standardizing on proactive condensate pan treatment schedules across all properties.
Technical Sourcing FAQs
Q: When is a condensate pump required instead of a gravity drain?
A: A condensate pump is required whenever the HVAC evaporator coil is located below the available drainage point (such as in a basement or crawlspace), or when the horizontal run to the drain is too long to maintain the required downward slope (typically 1/4 inch per foot). Condensate pumps use an internal float switch to automatically pump water vertically and horizontally to a suitable drain.
Q: How do condensate drain pan tablets prevent blockages?
A: Drain pan tablets contain slow-dissolving biocides and surfactants. As condensate water flows over the tablets, they slowly release active ingredients that prevent the growth of algae, slime, and mold in the drain pan. This prevents the formation of biological clogs that are the leading cause of condensate pan overflows.
Q: What is the purpose of a secondary condensate overflow switch?
A: A secondary overflow switch (or float switch) is installed in the secondary drain pan or directly in the primary condensate line. If the drain line becomes clogged and water begins to back up, the internal float rises, breaking the 24V control circuit to the thermostat. This immediately shuts down the cooling system, stopping condensate production and preventing an overflow.
Need Help Finding a Specific Rating, Size, or Brand?
Contact our commercial procurement team for bulk ordering support, custom specifications, or multi-site facility supply contracts.